Accedi

Single Phase Transformers

Panoramica

Source: Ali Bazzi, Department of Electrical Engineering, University of Connecticut, Storrs, CT.

Transformers are stationary electric machines that step up or down AC voltage. They are typically formed of primary and secondary coils or windings, where the voltage on the primary is stepped up or down at the secondary, or the other way around. When a voltage is applied to one of the windings and current flows in that winding, flux is induced in the magnetic core, coupling both windings. With an AC current, AC flux is induced, and its rate of change induces voltage on the secondary winding (Faraday's law). Flux linkage between both windings depends on the number of turns of each winding; therefore, if the primary windings have more turns than the secondary winding, voltage will be higher on the primary than on the secondary, and vice versa.

This experiment characterizes a single-phase transformer by finding its equivalent circuit parameters. Three tests are performed: open-circuit test, short-circuit test, and the DC test.

Procedura

1. DC Test

  1. Turn on the low-voltage DC power supply available on the bench.
  2. Set its voltage output to 0 V, and set the current limit to 0.8 A.
  3. Double-check the circuit connections, then connect the power supply output across the primary side windings (IN1 and IN2). Leave the secondary side windings (OUT1 and OUT2) open.
  4. Turn on the supply and slightly increase the voltage until the current limit is reached. Note that the supply might already be current-limited when the supply is t

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Risultati

By performing the DC, open-circuit, short-circuit, and load tests, the transformer's equivalent circuit parameters were identified; therefore, simulating, operating, and analyzing realistic transformer behavior become possible.

The short circuit test is usually performed by applying an increasing voltage on the high voltage side, since only small voltages on that side may cause rated current to flow on the shorted low voltage side. This is useful in operating the transformer at rated curre

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Tags
Single Phase TransformersPower SuppliesAC VoltagesAC CurrentsElectrical IsolationLaboratory InstrumentsMedical DevicesTransformer ComponentsTransformer AnalysisTransformer DesignElectrical ParametersTestsPrimary WindingSecondary WindingCoreSteel CoreFerrite CoreAir CoreMagnetic CouplingMagnetic FieldMagnetic FluxMutual InductionFaraday s LawInduced Voltage

Vai a...

0:06

Overview

1:05

Principles of Single-phase Transformers

4:25

DC Test for Winding Resistance

6:26

Open Circuit Test

7:46

Short Circuit Test

9:06

Applications

10:30

Summary

Video da questa raccolta:

article

Now Playing

Single Phase Transformers

Electrical Engineering

20.1K Visualizzazioni

article

Electrical Safety Precautions and Basic Equipment

Electrical Engineering

144.5K Visualizzazioni

article

Characterization of Magnetic Components

Electrical Engineering

15.0K Visualizzazioni

article

Introduction to the Power Pole Board

Electrical Engineering

12.4K Visualizzazioni

article

DC/DC Boost Converter

Electrical Engineering

56.7K Visualizzazioni

article

DC/DC Buck Converter

Electrical Engineering

21.1K Visualizzazioni

article

Flyback Converter

Electrical Engineering

13.2K Visualizzazioni

article

Single Phase Rectifiers

Electrical Engineering

23.4K Visualizzazioni

article

Thyristor Rectifier

Electrical Engineering

17.4K Visualizzazioni

article

Single Phase Inverter

Electrical Engineering

17.9K Visualizzazioni

article

DC Motors

Electrical Engineering

23.3K Visualizzazioni

article

AC Induction Motor Characterization

Electrical Engineering

11.6K Visualizzazioni

article

VFD-fed AC Induction Machine

Electrical Engineering

6.9K Visualizzazioni

article

AC Synchronous Machine Synchronization

Electrical Engineering

21.5K Visualizzazioni

article

AC Synchronous Machine Characterization

Electrical Engineering

14.2K Visualizzazioni

JoVE Logo

Riservatezza

Condizioni di utilizzo

Politiche

Ricerca

Didattica

CHI SIAMO

Copyright © 2025 MyJoVE Corporation. Tutti i diritti riservati