A subscription to JoVE is required to view this content. Sign in or start your free trial.
This work aims to facilitate the development of standardized techniques for impregnating or grafting aminated compounds onto silica substrates, which are often broadly described in the literature. Specific amounts of solvent, substrate, amines, and the values of other important experimental parameters will be discussed in detail.
Recently, there has been a significant effort towards reducing or mitigating CO2 emissions through the use of carbon capture materials for point source or direct air capture (DAC) methods. This work focuses on amine-functionalized CO2 adsorbents for DAC. These materials show promise for CO2 removal because they have low regeneration energy consumption and high adsorption capacity. The incorporation of amine species into a porous substrate combines the advantages of the amine species' affinity to CO2 with the large pore volumes and surface areas of the porous substrate. There are three methods commonly used to prepare amine-based CO2 sorbents, depending on the selection of the amine species, material support, and preparation method. These methods are impregnation, grafting, or chemical synthesis. Silica is a prevalent choice of substrate material because of its adjustable pore size, moisture tolerance, temperature stability, and ability to adsorb CO2 in low concentrations for DAC applications. Typical synthetic procedures and primary attributes of both impregnated and grafted amine-silica composites are described herein.
The anthropogenic CO2 emissions over the past several decades have been widely implicated as the main factor driving the greenhouse gas effect and consequently, related climate change1,2,3,4. There are two general methods for CO2 capture, point source and direct air capture. For more than 50 years, wet-scrubbing CO2 capture technologies have been utilized for point source capture within the industry to mitigate CO2 emissions5,6. These technologies are based on liquid-phase amines that react with CO2 to form carbamates under dry conditions and hydrogen carbonates in the presence of water7,8, see Figure 1. The main reason that carbon capture and storage is utilized at large point (industrial) sources is to prevent the further release of large quantities of CO2, thus having a neutral effect on total CO2 concentration in the atmosphere. However, point-source carbon capture systems suffer from several drawbacks, such as equipment corrosion, solvent degradation, and high energy requirements for regeneration9. Direct air capture (DAC) goes beyond emission reduction and can facilitate the removal of CO2 from the atmosphere. The removal of this existing CO2 is necessary to limit continued climate change. DAC is an emerging methodology and must address the difficulties of removing low concentrations of CO2 in atmospheric conditions (400 to 420 ppm), operate in a variety of different environmental conditions, and address the need for cost-effective materials that can be reused many times1,2,3. Significant work is needed to identify materials that meet these requirements, which will accelerate the adoption of DAC and improve its economic feasibility. Most importantly, community consensus on critical parameters of measurement needs to be established, which is essential for benchmark materials to be developed.
Figure 1: Schematic of the expected liquid amine adsorbent CO2 capture mechanism. The top reaction is in dry conditions, and the bottom reaction is in the presence of moisture. Please click here to view a larger version of this figure.
In an effort to remedy these drawbacks, considerable research and development of novel porous material technology have resulted in a wide array of promising materials that have the potential to be utilized as either capture materials or substrates for DAC. Some examples of such materials include mesoporous silica species10,11,12,13, zeolites14,15, activated carbon16,17, and metal-organic frameworks18. Many solid-supported amine adsorbents also show a higher tolerance to water, which is a vital consideration in CO2 removal through DAC approaches. For DAC applications, researchers must consider wet/dry environmental conditions, hot/cold temperatures, and an overall dilute atmospheric CO2 concentration. Amongst the various substrate materials, silica is commonly used because of its adjustable pore sizes, ability to surface functionalize, and large surface area1,2,3. Typical synthetic procedures and primary features of both impregnated and grafted amine-silica composites are described within this work (Figure 2). Direct synthesis, where the material is made in situ with both components, substrate and amine, is another commonly used methodology2.
Figure 2: Schematic representations of impregnation. Mixing of PEI and silica substrate in methanol through diffusion (top) and grafted amine-silica composites through covalent tethering (bottom). Please click here to view a larger version of this figure.
ImpregnationΒ is a method in which an amine is physically adsorbed onto a surface, in this case, a porous silica medium, through van der Waals forces and hydrogen bonding between the amine and silica surface19,Β see Figure 2. Solvents such as ethanol and methanol are commonly used to promote the diffusion of the molecules into the porous structure of the substrate material. The solution can also be heated to increase the solubility of the high molar mass polyamines, thereby increasing the homogeneity of amine penetration within the pores. In the case of impregnated materials, the amount of amine introduced to a silica substrate is determined by the initial quantity of the amine and the surface area of the substrate. If the amount of amine introduced exceeds the available surface area of the silica substrate, the amine species will agglomerate on its surface. This agglomeration is readily apparent, as the impregnated material will appear to have a gel-like coating, often yellow, rather than the expected white and powdery appearance1. Among the many types of amine-base solid adsorbents, polyethyleneimine (PEI) and tetraethylene pentamine (TEPA) are the most widely used due to their high stability and high nitrogen content20. For physically impregnated systems, the theoretical loading quantity of amine can be calculated from the pre-weighted amounts of the substrate and the density of the amine. The obvious advantage of physical impregnation lies in the straightforward synthesis procedure to prepare it, as well as the potential for a large amine content due to the high porosity of the silica substrate. Conversely, the stability of the amine within the silica is limited because there is no covalent bonding between the amine and silica support. Therefore, after multiple cycles of CO2 uptake and regeneration through heat or steam, the amine can leach out of the pores. Despite these drawbacks, the implementation of such materials for DAC holds great promise for removing CO2 from the atmosphere.
Another option for the preparation of DAC materials is grafting. Grafting is a method through which amines are immobilized onto a porous silica substrate through a chemical reaction, as shown in Figure 2. This reaction proceeds by reacting an aminosilane with the surface's silanol functional group, resulting in a covalent bond. Therefore, the number of functional groups on the surface of the silica substrate impacts the grafted amine density21,22. Compared to amine-impregnated adsorbents, chemical grafting methods have had lower CO2 adsorption capacity mainly due to the low amine loading21. Conversely, chemically-grafted amines have increased thermal stability due to their covalently bound structure. This stability can be useful in the regeneration of the material as adsorbents (such as grafted silica) are heated and pressurized to remove the captured CO2 for reuse to save material and cost. In a typical synthesis procedure, the mesoporous silica substrate is dispersed in a solvent (e.g., anhydrous toluene), which is then followed by the addition of aminosilanes. The resulting sample is then washed to remove unreacted aminosilanes. Improvements in aminosilane density are reported to have been achieved through water addition, specifically with SBA-15, to expand pore size23. The procedure for grafting that will be described herein uses moisture-sensitive techniques. Therefore, additional water will not be used. Implementation of grafted aminosilane materials for DAC is promising due to their expected stability during CO2 adsorption and desorption processes. However, the major drawbacks of this methodology include the complex reactions/preparation of these materials, leading to increased cost, and their overall low CO2 adsorption capacity, meaning larger quantities are required.
Overall, results of many previous studies indicate that the structure of the substrate and amine-related modification has a significant impact on the adsorption performance with specific studies utilizing techniques such as transmission electron microscopy (TEM) and quasi-elastic neutron scattering (QENS) to fully characterize these materials24,25. In other words, the structural properties (e.g., porosity and surface area) of the substrate material determine the amine loading, so increasing these parameters can improve CO2 capacity24,25. Continued research into the optimization and design of substrate materials and preparation processes is critical to the development of high-performance adsorbents for DAC. The goal of this work is to provide guidance on impregnation and grafted amine synthesis in hopes of facilitating better transparency of synthetic techniques. Within the literature, specific details on the amounts of solvent, substrate, and amines are not always described, making it difficult to understand the correlation between experimental loading amounts and quantitative measurements of amine-silica composites. The exact loading amounts and a detailed description of the experimental procedures will be provided herein to better facilitate these types of comparisons.
NOTE: Details related to the equipment, instrumentation, and chemicals used in this section can be found in the Table of Materials.
1. Impregnation of silica with polyethyleneimine of 800 g/mol molar mass (PEI 800)
Figure 3: Representative images of reactions. (A)Β Photograph of PEI-silica slurry (in methanol) during PEI impregnation prior to transfer to a heating block and (B) apparatus for grafting of DAS after heating for 6 hours is completed. Please click here to view a larger version of this figure.
Figure 4: Representative appearance of end products after drying. (A) PEI impregnation at wamine_exp_imp = 59.9 %. (B) grafted DAS at wamine_exp_das = 90.0 %. Please click here to view a larger version of this figure.
2. Preparation of wet grafted silica with N'-(3-trimethylsilyl propyl) diethyleneamine (DAS)
Figure 5: Photographs of a sure-seal container. (A) Container with a needle connected to an inert gas (N2 or Ar2) and (B) with inert gas connected and gas tight syringe attached, with 'bent' needle (blue arrow), that will be used to transfer without leakage. Please click here to view a larger version of this figure.
3. Analysis of silica-composite materials by TGA
NOTE: The standard uncertainty associated with this measurement is approximately Β± 0.01 % in mass and Β± 1 Β°C in temperature.
4. Analysis of silica-composite materials by Fourier transform infrared spectroscopy (FTIR) using an attenuated total reflectance (ATR) accessory
NOTE: Standard uncertainties associated with this instrument are Β± 1 % in peak intensity and Β± 4 cmβ1 in wavenumber, therefore, the uncertainty in intensity in the reported curve is Β± 1.4 % using a linear propagation of uncertainties.
5. Analysis of silica-composite materials before and after impregnation and grafting of amines by scanning electron microscopy (SEM)
TGA is commonly used to quantify the amount of amine loaded or grafted to the silica surface for these materials. The obtained TGA curves show a loss of residual solvent and water between 60 Β°C to 100 Β°C, which is shown in the derivate weight (weight %/Β°C) curve as the first peak, and a loss of amine, which is shown in the derivate weight curve (weight %/Β°C) as the second peak. For PEI-impregnated silica, this loss of amine is expected to appear around 200 Β°C to 300 Β°C, which appears as the ...
The methods described herein are intended to provide a protocol for preparing impregnated and grafted amine silica-composite adsorbents. The procedures we have documented are based on review of techniques reported in the literature and those refined in our laboratory.1,2,3. Preparation of these materials is useful within the field of carbon dioxide removal research to develop or benchmark other materials that may be used to lowe...
All authors disclose no competing conflicts of interest. The full description of the procedures used in this paper requires the identification of certain commercial products and their suppliers. The inclusion of such information should in no way be construed as indicating that such products or suppliers are endorsed by NIST, or are recommended by NIST, or that they are necessarily the best materials, instruments, software or suppliers for the purposes described.
Charlotte M. Wentz would like to acknowledge funding through NIST Award # 70NANB8H165. Zois Tsinas would like to acknowledge funding through NIST Award # 70NANB22H140.
Name | Company | Catalog Number | Comments |
Anhydrous methanol | Sigma-Aldrich | 322415 | Does not come with sure-seal |
Anhydrous toluene | Sigma-Aldrich | 244511 | Comes with sure-seal |
Ceramic Stirring Hot Plate | NA | NA | The size, watage, and thermal capabilities of the stirr plate will differ depending on individual lab facilities. |
Fourier Transform Infrared Spectroscopy (FTIR)Β | Nicolet i550 series spectrometer | NA | Run on OMNIC standard software |
Gastight syringeΒ | NA | NA | As long as the gas tight syringe has a PTFE plunger and luer tip, is suited for air sensitive technique and can be used in this protocol.Β |
Glass vial | NA | NAΒ | As long as the vial is made if borosilicate glass and has a screw based cap the brand name, size, or general shape does not matter for the protocol. |
MCM-41 silica | ACS MaterialΒ | MSM41A01Β | Cas no. 7631-86-9 |
Metal needle | NA | NA | Syringe needles need to be stainless steel. It is recommended to determine length and outerdiameter of needle by what will be transferred using the gas tight syringe. For large quantities of liquid a larger outer diameter will improve transfer rates.Β |
Nβ-(3-trimethylsilyl propyl) diethyleneamine (DAS) | Sigma-Aldrich | 104884 | Comes with sure-sealΒ |
Polyethyleneimine (PEI) | Sigma-Aldrich | 408719 | Does not come with sure-seal |
Schlenk round bottom flask | ChemGlass AirFree | NA | As long as the flask is suited for high pressure and temperture but the brand name, size, or general shape does not matter for the protocol |
Thermogravemetric Anlysis (TGA)Β | TA Advantage | NA | 550 series from Waters and TA Instruments |
Request permission to reuse the text or figures of this JoVE article
Request PermissionThis article has been published
Video Coming Soon