Source: Ali Bazzi, Department of Electrical Engineering, University of Connecticut, Storrs, CT.

Three-phase wound-rotor synchronous generators are the main source of electrical power worldwide. They require a prime mover and an exciter in order to generate power. The prime mover can be a turbine spun by fluid (gas or liquid), thus the sources of the fluid can be water running off a dam through a long nozzle, steam from water evaporated using burned coal, etc. Most power plants including coal, nuclear, natural gas, fuel oil, and others utilize synchronous generators.

The objective of this experiment is to understand the concepts of adjusting the voltage and frequency outputs of a three-phase synchronous generator, followed by synchronizing it with the grid. The effects of field current and speed variations on the generator output power are also demonstrated.

手順

1. Prime-Mover Initialization

The prime-mover in this experiment is the dynamometer, which operates as a motor that spins the generator rotor (field).

  1. Make sure the three-phase disconnect switch, synchronous motor switch, and DC motor switch are all off.
  2. Check that the VARIAC is at 0%.
  3. Wire the VARIAC to the three-phase outlet and connect the setup shown in Fig. 1.
    1. Use the three-phase switch on the synchronous machine side as "S1."

Log in or to access full content. Learn more about your institution’s access to JoVE content here

結果

The desired speed of the prime-mover is set at 1,800 RPM since the synchronous machine has four poles (P) and operates at a frequency f= 60 Hz, thus synchronous speed is 120f/P= 1,800 RPM.

When synchronizing the synchronous machine (generator) to the grid, the machine's prime-mover provides rotation, but a magnetic field on the machine's rotor should be provided. This is achieved using

Log in or to access full content. Learn more about your institution’s access to JoVE content here

申請書と概要

Synchronous generators are the backbone of electricity generation in power plants worldwide. Synchronizing a generator to the grid has become standard practice and is typically automated by matching the phase sequences, voltage magnitudes, and frequencies of the generator to the grid. Voltage control using the rotor magnetic field is achieved using "exciters," while frequency control is achieved using the speed control of a turbine or prime-mover, providing rotation using steam, wind, water, or other fluids. Frequency co

Log in or to access full content. Learn more about your institution’s access to JoVE content here

タグ
AC Synchronous MachineSynchronizationSynchronous GeneratorPower GridPhase SequenceVoltage MagnitudeFrequencyAutomatic SynchronizersManual SynchronizationThree phase Synchronous GeneratorsVoltage AdjustmentFrequency AdjustmentRotorStatorMagnetic FieldOscillationsSupply Line Current

スキップ先...

0:06

Overview

0:54

Principles

3:13

Prime-Mover Initialization

5:04

Synchronizing the Synchronous Generator with the Grid

7:34

Applications

8:33

Summary

このコレクションのビデオ:

article

Now Playing

AC Synchronous Machine Synchronization

Electrical Engineering

21.5K 閲覧数

article

Electrical Safety Precautions and Basic Equipment

Electrical Engineering

144.5K 閲覧数

article

Characterization of Magnetic Components

Electrical Engineering

15.0K 閲覧数

article

Introduction to the Power Pole Board

Electrical Engineering

12.4K 閲覧数

article

DC/DC Boost Converter

Electrical Engineering

56.7K 閲覧数

article

DC/DC Buck Converter

Electrical Engineering

21.1K 閲覧数

article

Flyback Converter

Electrical Engineering

13.2K 閲覧数

article

Single Phase Transformers

Electrical Engineering

20.1K 閲覧数

article

Single Phase Rectifiers

Electrical Engineering

23.4K 閲覧数

article

Thyristor Rectifier

Electrical Engineering

17.4K 閲覧数

article

Single Phase Inverter

Electrical Engineering

17.9K 閲覧数

article

DC Motors

Electrical Engineering

23.3K 閲覧数

article

AC Induction Motor Characterization

Electrical Engineering

11.6K 閲覧数

article

VFD-fed AC Induction Machine

Electrical Engineering

6.9K 閲覧数

article

AC Synchronous Machine Characterization

Electrical Engineering

14.2K 閲覧数

JoVE Logo

個人情報保護方針

利用規約

一般データ保護規則

研究

教育

JoVEについて

Copyright © 2023 MyJoVE Corporation. All rights reserved