A subscription to JoVE is required to view this content. Sign in or start your free trial.
This novel protocol entails the quantification of cardiovascular calcification progression from serial micro positron emission tomography (PET)/micro computed tomography (CT) images in small research animals.
Micro positron emission tomography (PET) and micro computed tomography (CT) imaging are powerful, ideal research tools for following the progression of cardiovascular calcification. Due to their non-invasive nature, small research animals can be imaged at multiple time points. The challenge lies in the accurate quantification of cardiovascular calcification. Here, we provide a protocol, using images from the later disease stages as a template, to accurately quantify the progression of cardiovascular calcification in longitudinal studies. The protocol involves 1) the alignment of the chest area in multiple images from the same animal during a longitudinal study as the first step, 2) the definition of a region of interest (ROI) situated within the heart and the aorta at the site of larger calcium deposits that become apparent in later images, and 3) simultaneous segmentation and quantification of calcium deposits across all images acquired during the longitudinal study. This streamlined method enhances the accuracy of image analysis in following the progression of cardiovascular calcification by improving the precision of ROI definition and reducing the variability associated with earlier techniques that analyze individual scans independently.
Cardiovascular disease is a leading global cause of morbidity and mortality, demanding rigorous exploration to uncover its mechanisms and to devise effective preventive and therapeutic strategies. Coronary artery calcification (CAC) is widely acknowledged by the experts in the field as a predictive factor for cardiovascular disease, significantly elevating the risk of cardiovascular mortality1,2,3,4,5. Microscopic calcifications are considered the earliest stages of calcific atherosclerosis, and the term "microcalcifications" has been used to refer to calcium deposits between 0.5 to 50 µm6,7,8,9 in diameter. These small calcifications are believed to coalesce to form larger calcium deposits, fueling the progression of calcific plaque6,7.
Positron emission tomography (PET) and computed tomography (CT) serve as valuable research tools, frequently employed for the non-invasive assessment of cardiovascular calcification in vivo5,10,11,12,13,14,15,16,17,18,19. These imaging modalities prove particularly advantageous for tracking vascular calcification progression in longitudinal studies involving small research animals11,12,13,19. MicroCT imaging has demonstrated effectiveness in providing anatomical images of relatively large calcium deposits11,12,13,19,20. However, its utility for imaging small calcium deposits in living animals is constrained by its spatial resolution of ~100 µm8,14, making it challenging to investigate calcification during its initial phases.
A notable advancement is the adoption of combined microPET/microCT imaging with the PET tracer, fluoride-18-labeled sodium fluoride (18F-NaF), as the standard method for the detection of calcification based on its binding to the mineral surface area. This approach uses radiolabeled 18F-NaF, shown to identify the calcium mineral surface10,13 as the fluoride ions bind covalently to calcium hydroxyapatite, replacing hydroxyl groups to form fluoroapatite21. Consistent with the slower exchange rate relative to the radioactive decay of the 18F (half-life ~110 min) and to the clearance of the tracer through kidneys22, Irkle and colleagues13 found that 18F-NaF binding to calcified carotid specimens was limited to the surface at the time of detection. Thus, tracer uptake should relate directly with mineral surface area, which is greater when a given amount of mineral occurs in multiple small foci or in porous form than when present in few, large, solid deposits. By accentuating the earliest stages of mineralization with high sensitivity, 18F-NaF PET imaging may provide valuable insights into the early stages of disease, making it particularly useful in studying preventive as well as therapeutic strategies13,14,15.
Even with recent advancements in the combined microPET/microCT imaging of vascular calcification, there are opportunities for improving the accuracy of image analysis in longitudinal, cardiovascular calcification studies. Conventional approaches use labor-intensive, manual delineation of regions of interest (ROI) around each visible calcified region in every mouse at each individual time point throughout the longitudinal study. This method reduces precision, particularly in the early disease stages when the sizes of calcium deposits approach the scanners' detection limits, potentially making invisible some areas with minuscule deposits arranged in low density.
In the realm of imaging, alignment generally refers to the spatial alignment of a series of images. Introducing alignment as a novel solution to the existing challenges, our proposed method allows investigators to use a consistent location for following the progression of calcification in serial images from individual subjects throughout a longitudinal study. Given that tissue calcification is known to arise from nanosized matrix vesicles (50-150 nm), which coalesce to form microscopic, then macroscopic hydroxyapatite mineral23, one may retrospectively identify where microcalcifications would have been located in early images before they are discernable.
Following that same location over time, made possible by image alignment, is the basis for this method. It obviates the need to identify the earliest calcification stages directly, as the ROI is assigned based on the latest stages when mineralization is readily identified. In this protocol, we present an improved, streamlined data analysis method that incorporates the alignment of a time series of images as a vital step, enhancing accurate quantitation of calcium deposition in longitudinal, combined, microPET/microCT imaging studies (Figure 1). While we use PET/CT data analysis as an example, this method can be applied to the analyses of other longitudinal imaging data, including single photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), and optical imaging24.
Figure 1: Protocol overview flowchart. Flowchart summarizing the novel protocol for quantifying cardiovascular calcification. General steps include longitudinal imaging, alignment of images acquired at different time points, and segmentation and quantification of the calcified region. Please click here to view a larger version of this figure.
The representative images present a female apolipoprotein-E-deficient (Apoe-/-) mouse. Experimental protocols were reviewed and approved by the Institutional Animal Care and Use Committee of the University of California, Los Angeles.
1. Animal scanning
2. Import DICOM files in DICOM viewer software
NOTE: While this representative protocol uses ORS Dragonfly software under a non-commercial license, its flexibility extends to other DICOM viewer software options.
3. Adjust DICOM viewer settings to optimize image visualization
Figure 2: Adjustment of DICOM viewer settings to optimize image visualization. (A,B) Coronal view of CT images (A) before and (B) after contrast/brightness adjustment. (C,D) Coronal view of PET/CT images (C) before and (D) after Lookup Table adjustment. Abbreviations: CT = computed tomography; PET = positron emission tomography. Please click here to view a larger version of this figure.
4. Align the chest area in CT images
NOTE: For simplicity, one CT image will serve as the "base" image and will not be translated or rotated. The second CT image (and eventually subsequent serial images) will be translated and/or rotated to align with the base image; this will be called the "overlay" image for the purpose of the demonstration. Throughout alignment, it is important to distinguish between the base image and all other overlay images.
Figure 3: Alignment of all CT images. (A,B) Coronal view of base (gray) and overlay (red) CT images (A) before and (B) after alignment. (C,D) Sagittal view of CT images (C) before and (D) after alignment. Blue arrows indicate the mouse (1) thoracic cage, (2) spine, and (3) sternum. Abbreviation: CT = computed tomography. Please click here to view a larger version of this figure.
5. Co-register PET images with corresponding CT images
NOTE: Alignment of the overlay CT image and base CT image will initially result in misalignment of the overlay CT image with its respective PET image seen in Figure 4. The PET image needs to be co-registered with its corresponding CT image once again.
Figure 4: Alignment of PET images with corresponding CT image. A representative PET image and its corresponding CT image (A, C) before and (B, D) after co-registration. Following completion of co-registration, the PET and CT images should be aligned as demonstrated in Panel B. Abbreviations: CT = computed tomography; PET = positron emission tomography. Please click here to view a larger version of this figure.
6. Identify cardiovascular calcification
Figure 5: Identifying calcified regions in the heart. Calcification regions depicted in representative (A) sagittal, (B) transverse, and (C) coronal CT images, as well as (D) a coronal PET/CT image. Yellow arrows indicate calcium deposits. Blue arrows identify reference structures used for determining the location of calcification. Abbreviations: CT = computed tomography; PET = positron emission tomography. Please click here to view a larger version of this figure.
7. Draw ROIs around the calcified regions
Figure 6: Using segmentation to restrict the ROI to calcified regions. (A) The arrows guide through the steps required to eliminate undesired density data from the ROI. The blue arrow points to the Segment tab; the yellow arrow highlights the Define Range feature; green arrows indicate the selected range inputs; and the red arrow points to the Remove button. (B) Following completion of protocol steps 7.4-7.4.3, the ROI should specifically delineate the calcified regions, as depicted in this panel. Abbreviation: ROI = region of interest. Please click here to view a larger version of this figure.
8. Quantify the ROI for each image
Figure 7: ROI quantification. The Statistical Properties tab for a selected ROI. The red arrows illustrate steps required to obtain statistical information for a dataset based on the ROI. The red boxes identify the volume and the mean Hounsfield unit value, essential for further analysis calculations. Abbreviation: ROI = region of interest. Please click here to view a larger version of this figure.
Analysis methods
This section illustrates successful utilization through representative results. Here, we showcase the combined microPET/microCT image of a single mouse scanned at 15 and 18 months of age, after subjected to a Western diet (21% fat, 0.2% cholesterol) from 12 through 14 months of age. Following protocol sections 2-8 for calcification quantification, four independent researchers separately measured volumetric calcium content and 18F-NaF PET activity using the same represent...
This novel protocol is an improved approach to the quantification of cardiovascular calcification. Due to the non-invasive nature of imaging, longitudinal microCT images may be acquired to follow the progression of cardiovascular calcification in small animals. Although microCT images alone can show the progression of calcium content, microPET images, when available, can provide additional levels of information, especially its enhanced detection of small calcium deposits due to tracer binding to surface area. For further...
The authors have no conflicts of interest to declare.
We thank all members of the UCLA Crump Preclinical Imaging Technology Center for their help with data acquisition and procession as well as equipment and infrastructure maintenance. We thank Jeffrey Collins for his help with cyclotron operation and 18F-NaF synthesis. We thank the UCLA Statistical Consulting Group for their help with statistical analysis. This work is supported by the NIH Cancer Center Support Grant (2 P30 CA016042-44 to MT) and National Institutes of Health, Heart, Lung, and Blood Institute (HL137647 and HL151391 to YT and LLD). The GNEXT PET/CT scanner was funded by NIH S10 Shared Instrumentation for Animal Research Grant (1S10OD026917-01A1 to Arion Chatziioannou).
Name | Company | Catalog Number | Comments |
0.5 cc Sterile Insulin Syringes | Exel International | #26028 | Used for IV injection of 18F-NaF PET Tracer |
18F-NaF PET Tracer | CNSI Cyclotron | ||
Biorender | Biorender | Used for figure 1 | |
Female Apoe-/- mouse | Jackson Laboratories | #002052 | B6.129P2-Apoetm1Unc/J |
GNEXT PET/CT | Sofie Biosciences, Dulles, Virginia | ||
Isoflurane | Piramal Critical Care | Used as anesthesia for mouse imaging | |
ORS Dragonfly | Comet Technologies Canada Inc. | ||
SPSS Statistics | IBM | ||
Western diet for mice | Envigo | #TD88139 | 21% fat, 0.2% cholesterol |
Request permission to reuse the text or figures of this JoVE article
Request PermissionThis article has been published
Video Coming Soon
Copyright © 2025 MyJoVE Corporation. All rights reserved